• Insulated Glass Windows - Custom Sizes for Projects
  • Insulated Glass Windows - Custom Sizes for Projects
  • Insulated Glass Windows - Custom Sizes for Projects
  • Insulated Glass Windows - Custom Sizes for Projects
  • Insulated Glass Windows - Custom Sizes for Projects
  • Insulated Glass Windows - Custom Sizes for Projects

Insulated Glass Windows - Custom Sizes for Projects

No.LYD-IGUW
Insulated Glass Windows
Glass thick
3mm,3.2mm,4mm,5mm,6mm,8mm,10mm,12mm
Edge processing
Seamed Edge, Round edge ,Flat edge
Aluminum spacers
6A,9A,12A,14A,16A,19A,22A etc
Sealant
Silicone sealant, Structural silicone sealant
Min Size 
100mm*100mm
Max Size
3660mm*2440mm
Port of Loading 
Xingang port
Package
Plywood Crates,A-Steel Rack etc
  • Insulated Glass Windows - Custom Sizes for Projects
  • Insulated Glass Windows - Custom Sizes for Projects
  • Insulated Glass Windows - Custom Sizes for Projects

Description

Product Overview

An insulated glass unit is two or three panes held apart by a spacer bar, with the cavity between them filled with air, argon or krypton and sealed at the perimeter. That cavity is what does the work: it breaks the direct path a single pane gives heat to travel along, and it does the same to sound. Every unit leaves our line fully sealed, so it is glazed into the frame as one finished piece rather than assembled on site. The same range covers a bathroom sash and a full-height facade panel, which means one schedule can carry the whole envelope instead of splitting small units and large panels across different suppliers. Buyers come to insulated glass manufacturers for different reasons. A fabricator wants panels cut to fit profiles already on the bench. A specifier wants a build-up that meets an energy or acoustic target without redesigning the opening. We quote against your drawing rather than a stock list, so each of those is settled before production starts.

Construction of Insulated Glass Windows

Every unit is built around one idea: keep the cavity dry, keep it still, keep it sealed. Production starts with the glass: every order is custom insulated glass, so the panes are cut to the drawing and processed on the edges before anything else happens. The spacer frame is prepared next, and the two or three panes are brought together around it, one on each side, so the cavity is created at the same moment as the unit itself.

That order matters because the cavity cannot be opened again afterwards. Once the perimeter is closed the assembly is a single product: it cannot be re-gassed, re-dried or re-tensioned on site. This is the part of the build insulated glass manufacturers control most directly — how clean the cavity stays, how evenly the spacer meets both panes, and whether the seal runs unbroken around every corner.

Unit thickness is simply the sum of its parts: outer pane, spacer, inner pane. A 6 mm pane, a 16A spacer and a 6 mm pane give a 28 mm unit. That number is what your frame has to swallow, so we check it against the profile drawing before any glass is cut, and we hold it consistent across a run of double glazed units so glazing crews are not juggling different thicknesses on the same elevation.

1. The spacer frame is assembled to the unit perimeter, and every corner joint has to stay tight — a gap at a corner is where moisture gets in first. 2. A primary seal is applied to the spacer faces. Butyl rubber is the usual choice because it is the vapour barrier: it keeps moisture out and the gas fill in. 3. The panes and the spacer are brought together and pressed so the primary seal wets out evenly against both sheets, with no voids or channels left along the edge. 4. The secondary seal goes into the perimeter channel. We use silicone sealant for standard units, or structural silicone sealant where the unit is bonded into a structural glazing system and the seal also carries load. 5. Each unit is then cured, checked for seal continuity around the full perimeter and measured against the drawing before it is packed.

Spacer Bars and Desiccant

The spacer is the aluminum frame that sits between the panes and holds them exactly apart. Choosing a spacer is therefore choosing the depth of the insulating layer, and it changes two things at once: how much room the gas has to slow heat transfer, and how thick the finished unit becomes. Inside the spacer is a desiccant. Its job is to absorb the small amount of moisture left in the cavity when the unit is closed, so nothing condenses on the inside face of the glass in the first months. The desiccant only works if the perimeter holds, which is why spacer, sealant and glass are treated as one assembly rather than three separate parts. There is a practical limit to how far you widen the cavity. Past a certain point the gas inside starts to circulate and the gain flattens out, while the unit keeps getting thicker. The right spacer width for double glazed units usually falls out of three things at once: the frame rebate on your drawing, the energy target, and the sizes on the schedule. Aluminum is what we list for this product; if your specification calls for a low-conductivity or warm-edge spacer, tell us before we quote.

Types of Insulated Glass Windows

- Thickness from 3 mm to 12 mm. Each pane can be specified in 3 mm, 3.2 mm, 4 mm, 5 mm, 6 mm, 8 mm, 10 mm or 12 mm. Thicker panes add stiffness and weight, which matters on tall openings, large panels and lower floors where wind load and impact are higher. - Two panes or three. A double-glazed unit has one cavity; triple glazing adds a third pane and a second cavity. Triple builds are chosen where the energy target is demanding or the climate is severe, and they add thickness and weight the frame has to carry. - Insulated tempered glass. Tempered panes go into the unit wherever the glass sits in a door, a sidelight, a full-height panel or another position people can reach or fall against. If the pane breaks it comes apart into small blunt fragments instead of large shards. - Laminated insulated glass. A laminated pane holds together after impact, which keeps the opening closed, and the interlayer adds mass that helps with low-frequency noise. - Chosen per position. It is normal to run a lighter build on upper floors and a heavier one at ground level, or a heavier inner pane on an elevation facing a road. Send the elevation schedule and we will match each opening rather than applying one build to the whole job.

TypeBuild-upWhat it adds
Double-glazed windowsTwo panes, one sealed cavityThe standard step up from single glazing, in a familiar frame depth
Triple-glazed windowsThree panes, two cavitiesA second barrier for cold climates and low-energy buildings, at more thickness and weight
Low-E windowsLow-E coating on a cavity faceReflects heat back into the room, cuts UV transmission, keeps the daylight
Insulated tempered glassTempered panes sealed into the unitImpact strength and safety glazing behaviour for doors, sidelights and full-height panels
Laminated insulated glassLaminated pane built into the unitPost-break integrity and extra acoustic mass
Soundproof windowsThicker panes, wider cavity or an asymmetric buildTargeted noise reduction on elevations facing traffic, rail or flight paths

Benefits of Insulated Glass Windows

  • Energy efficiency. The sealed cavity breaks the conductive path a single pane gives heat. In winter it slows heat leaving the room, in summer it slows heat coming in, so the heating or cooling plant runs less to hold the same set point. A Low-E coating or a gas fill takes the same unit further.
  • Thermal insulation. Indoor temperature stays steadier because the glass surface no longer swings with the weather outside. Rooms hold their temperature between plant cycles, which is what occupants notice first.
  • Noise reduction. Sound crosses glass, then a cavity, then glass again, and each boundary takes energy out of it. A sealed unit is noticeably quieter than a single pane of the same thickness; heavier panes, laminated insulated glass or a wider cavity push it further.
  • Reduced condensation. The room-side pane stays warmer, so it is less likely to fall below the dew point and collect water. Kitchens, bathrooms and glazed entrances are where the difference shows first, and drier glass means less mould on frames and sills.
  • UV protection. Low-emissivity coatings block most ultraviolet light while letting daylight through, which protects flooring, upholstery, timber veneers, artwork and merchandise displays from fading on south and west elevations.
  • Increased comfort. No cold downdraft off the glass in winter and no radiant hot spot beside a west-facing window in summer, so rooms stay usable right up to the glass instead of a metre back from it.

Applications

Residential properties. Windows, doors and skylights in houses, apartments and residential developments. Bedrooms on a road side usually go for a heavier or asymmetric build, while kitchens and bathrooms gain most from a low-E coating, which keeps the room-side pane warmer.

Commercial buildings. Custom insulated glass panels for office towers, commercial storefronts, hotels and public buildings — curtain walls, fixed windows, punched openings and large glazed entrances where dimensions come off a drawing rather than a catalogue.

Industrial facilities. Factories, logistics centres, plant rooms and site offices, where the glass has to hold a controlled internal temperature without cutting the view into the workspace.

Sound-sensitive environments. Buildings near airports, rail corridors and arterial roads, where the acoustic build matters more than the thermal one and the pane build is chosen for noise first.

Interior partitions and doors. Meeting rooms, healthcare corridors, studio partitions and office fronts, where a sealed unit gives acoustic separation between two conditioned spaces and the door leaves are glazed in insulated tempered glass.

Renovation and replacement. One-to-one replacement of failed double glazed units in existing frames, where matching thickness and spacer width matters more than improving performance.

Specifications

PropertyValue
ModelLYD-IGUW
Glass thickness3 mm, 3.2 mm, 4 mm, 5 mm, 6 mm, 8 mm, 10 mm, 12 mm
Edge processingSeamed Edge, Round edge ,Flat edge
Aluminum spacer bars6A, 9A, 12A, 14A, 16A, 19A, 22A and other sizes
SealantSilicone sealant, Structural silicone sealant
Gas fillAir, argon or krypton
Unit buildDouble glazing (two panes) or triple glazing (three panes)
Minimum size100 mm × 100 mm
Maximum size3660 mm × 2440 mm
Port of loadingXingang port
PackingPlywood crates or A-Steel racks

Gas Fill

  • Argon. An argon gas fill is the usual choice for double and triple glazing. It is heavier and less conductive than air, so it slows convection inside the cavity, and it suits most cavity widths across the middle of the spacer range.
  • Krypton. A denser gas that performs better per millimetre of cavity. It is chosen when the unit has to stay thin — a slim frame, a shallow rebate, or a renovation where the new unit must fit the old profile.
  • Air. A unit can also be supplied air-filled where the specification does not call for a gas fill. It is a simpler build with lower performance than a gas-filled cavity.
  • Retention. The fill is only as good as the perimeter seal. Gas migrates out through a poor seal long before the glass itself fails, so seal continuity is checked before packing rather than assumed.

Maintenance

  1. Clean the glass with a soft cloth and a mild, non-abrasive cleaner. Scourers, blades and gritty pads leave fine scratches that show badly at low angles.
  2. Wash the room-side and weather-side faces normally — on a coated unit the low-emissivity surface sits inside the cavity, so routine cleaning never touches it.
  3. Twice a year, look along the edge of each unit for fogging, a white haze or droplets trapped between the panes. That is a seal failure rather than dirt, and cleaning will not shift it.
  4. Check the frame and glazing gaskets at the same time. Hardened, shrunken or missing gaskets let water sit against the unit edge, which is where seal problems start.
  5. Keep weep holes and drainage channels in the frame clear so water runs away from the unit instead of pooling along the bottom edge.
  6. If a unit does fail, replace the unit. The cavity cannot be re-dried or re-sealed in place, and a repair on site only hides the symptom.

Ordering and Delivery

  • Send the schedule. Finished width and height, glass thickness for each pane, spacer width, sealant, edge processing and quantity per size — custom insulated glass panels are made to that list, not to a stock size.
  • Check the unit thickness against your frame. Pane, spacer and pane add up to the overall thickness, and the rebate has to take it. Send the profile drawing with the schedule and we will check the fit before cutting.
  • Plan for the weight. A sealed unit is heavier than a single pane of the same area, so frame, anchors and hardware need to be sized for it, and large panels need lifting equipment on site.
  • Installation. Units are glazed as complete pieces, set on blocks rather than resting directly on the frame, with the perimeter gasket continuous all round.
  • Cost. A sealed unit costs more than single glazing of the same size. The return comes from heating and cooling load over the life of the building, and from units that do not need replacing every few years.
  • Packing and shipping. Units travel in plywood crates or A-Steel racks with export packing, loaded through Xingang port.
  • Terms. Lead time, payment terms and the warranty that applies to the units and to seal performance are confirmed by your sales contact once the schedule is fixed.
  • Supply. Orders run from a single replacement unit to a repeated project programme, and you deal directly with insulated glass manufacturers rather than through a reseller.

Scale & Supply Capability

LYD GLASS manufactures and exports glass for project buyers, fabricators and contractors who prefer to buy direct from a production source. Everything we supply is made to order: send drawings, sizes, quantities and finishing requirements, and we return a factory quotation against them. Panels are packed for export in plywood crates or A-Steel racks and protected for sea freight. We work to your delivery schedule, support repeat orders and answer specification questions before production starts. Send your requirements for a quote.

FAQ

Q1. What glass thicknesses can I specify for my order?

We supply 3 mm, 3.2 mm, 4 mm, 5 mm, 6 mm, 8 mm, 10 mm and 12 mm glass, and the thickness is chosen per opening rather than per order. Heavier panes go where the unit is large, exposed to wind load or within reach at ground level; lighter panes are usual on upper floors and smaller openings. Send the schedule and we will confirm a thickness for each position against your frame drawing.

Q2. Can I request different edge processing for the windows?

Yes — seamed edge, round edge or flat edge. Seamed edge is the usual finish where the glass sits inside a gasket and the edge is covered. Round and flat edges are specified where the edge stays exposed, where the frame detail calls for a particular profile, or where the glazing method needs a specific contact face. Tell us the frame system and we will match the edge to it.

Q3. What spacer sizes are available for custom double glazed windows?

Aluminum spacers come in 6A, 9A, 12A, 14A, 16A, 19A and 22A, among other sizes, and the number is the cavity width. A wider spacer gives the gas more room to work but also makes the unit thicker, so the choice is usually set by the frame rebate and the performance target together. Keep one spacer width across a frame series and vary it only where an opening genuinely needs something different.

Q4. Which sealants do you use in production?

We use silicone sealant and structural silicone sealant, depending on the application and how the unit is fixed. Both sit over a butyl primary seal on the spacer, and the secondary seal is what keeps the perimeter airtight and holds the assembly together. Structural silicone sealant is specified where the unit is bonded into the frame system rather than simply gasketed into it.

Q5. What size range can I order?

Custom insulated glass panels run from 100 mm × 100 mm up to 3660 mm × 2440 mm. Small units are usually door lites, transoms and cabinet-sized openings; the top of the range covers full facade panels. Send finished sizes as width × height, and flag any panel that sits close to the maximum so we can check handling and packing before production.

Q6. Can tempered glass be used in an insulated unit?

Yes. Insulated tempered glass is a standard build: the panes are heat-treated before assembly, so the finished unit gives both the thermal performance of a sealed cavity and the safety behaviour of tempered glass. It is the usual choice for doors, sidelights, full-height glazing and any position people can reach or fall against.

Q7. Can laminated glass be built into an insulated unit?

Yes. Laminated insulated glass combines a laminated pane — two sheets bonded with a PVB interlayer — with the sealed cavity. The interlayer keeps the pane together after impact, which holds the opening closed, and it adds mass that helps with low-frequency noise. It is often specified on street-facing elevations and in overhead glazing.

Leave a message
FirstName *
Email *
WhatsApp *
Message *
Please tell us the following information about your requirements: product model (product series), size, quantity
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.